Arc-flash garment manufacturerModule D certified · Module B Cat III rangeUK stock · next-day deliveryMen's & women's fits

We make arc flash garments. That's all we do.

We design, certify and make arc rated PPE in-house, with one of the largest Module B Cat III certified ranges in the UK.

Protection levels

How much arc flash protection do you need?

Your arc flash risk assessment gives an incident energy for each task, in cal/cm². Choose garments rated at or above that figure.

Your level

Everyday wear

Up to 8 cal/cm²

Single garments for lower-energy tasks and daily wear on site, each with its own rating.

  • Rated as an individual garment
  • Polos, shirts and trousers
Shop up to 8 cal/cm² →
Your level

Layered protection

Up to 25 cal/cm²

Base and outer layers tested together as a system, for tasks with higher incident energy.

  • Rating applies to the tested combination
  • Coveralls and outerwear
Shop 8–25 cal/cm² →
Your level

Complete systems

Up to 40 cal/cm²

Head-to-boot clothing systems for the highest-energy tasks, certified as a complete assembly.

  • Certified as a full assembly
  • Includes head and face protection
Shop 25–40 cal/cm² →

ATPV and ELIM: the two numbers on the label

Both come from the same open-arc test, EN 61482-1-1. ELIM is the lower, more conservative figure — if your risk assessment quotes ELIM, compare against ELIM.

Arc Thermal Performance ValueATPV

The incident energy a fabric withstands before the onset of a second-degree burn.

Shop by ATPV →
Incident Energy LimitELIM

The incident energy below which no burn injury is predicted. Always the lower of the two figures.

Shop by ELIM →
Some fabrics report EBT (Energy Breakopen Threshold) instead of ATPV, where the fabric breaks open before the ATPV level is reached.

Box test · IEC 61482-1-2

APC 1 or APC 2?

The box test directs a constrained arc at the garment at a set current: 4 kA for APC 1, 7 kA for APC 2. It's a pass or fail result, recorded alongside the cal/cm² rating.

Higher-energy work such as switching and fault-level tasks, and layered systems, call for APC 2. Your risk assessment sets the class.

APC 14 kA

Pass/fail at 4 kA constrained arc. Matched to single-layer garments and Class 1 clothing systems.

Shop APC 1 garments →
APC 27 kA

Pass/fail at 7 kA constrained arc. Required for higher incident-energy tasks and layered systems.

Shop APC 2 garments →

Find your level

Got a figure from your risk assessment?

Enter it and we'll list every garment rated at or above it.

Do you know the minimum cal/cm² for the task?

Woman wearing Vailos hi-vis orange arc-flash polo and trousers

Women's range

Arc flash clothing
cut for women.

No rolled-up sleeves or gathered waistbands. Coveralls, trousers, hoodies and waterproofs sized for women, each with its own ATPV and ELIM rating.

Arc flash helmets & hoods

Protection doesn't stop at the collar.

Arc flash helmets with flip-down visors, and hoods with a hard hat. Choose head protection to suit the clothing underneath.

Check the current product documentation and ask our team to confirm the rating for your risk assessment.

Police & public order

Full police range available.

Vailos supplies a full range of police garments, with customisation options. Tell us your force's requirements and we'll specify the range around them.

  • Full police garment range
  • Customisation options
  • Specified to your requirements
  • Quotes for force-wide orders
Police officer in a high-visibility vest, seen from behind

Protection builder

Build your arc flash protection,
layer by layer.

Set the cal/cm² your risk assessment calls for, then choose a garment for each layer. Only garments rated at or above your figure are shown. Add your company logo and see it on the real garment before you order or request a quote.

  1. Protection levelThe cal/cm² from your risk assessment
  2. Layer by layerBase, mid, core, outer, head & face
  3. Your logoPlaced on the real garment, in as many positions as you need
  4. Order or quoteAdd the kit to your basket or send it to our team
Start building →
Your kit, layer by layer5 layers
  1. LEMGO1Base layerLEMGO
  2. HAGEN2Mid layerHAGEN
  3. GOSLAR3Core garmentGOSLAR
  4. RATINGEN4Outer layerRATINGEN
  5. Arc flash helmet5Head & faceArc flash helmet

One garment per layer, matched to the protection level you set. Add your logo in any position, then order online or request a quote.

Start building →

Why Vailos

Why safety teams specify Vailos.

Inherent protection

The protection is in the fibre, so it doesn't wash out over the life of the garment.

Made to be worn all shift

Lighter fabrics and cuts that move. A garment left in the van protects no one.

Arc-safe branding

Your logo applied using arc-safe branding methods.

Trade and procurement support

Trade pricing, volume quotes and account support for distributors and large employers.

Technical documentation

The paperwork for your audit.

Request datasheets, Declarations of Conformity and certification for any garment.

Industries

Arc flash clothing for your industry.

How we work

From your risk to the right garment.

  1. 1

    Meet your team and set the standard

    We meet your teams, understand the work they do and where the risk sits, and set your arc flash standard together.

  2. 2

    Specify the right garment for each job

    We tell you what to specify for each kind of job. Many teams issue one default garment to everyone and pay for protection some roles do not need. Matching the rating to the job cuts that cost.

  3. 3

    Supply the garments

    We supply the right garments from our own certified range, in UK stock with next-day delivery, customised where needed.

Set your arc flash standard with a specialist.

Vailos helps you set your arc flash standard, then supplies the certified garments that meet it. Talk to a specialist about incident energy, ratings and complete tested systems.